TROVIS SAFE 3731-3
Electropneumatic Ex d positioner with HART® communication
PRODUCT
						Positioner
					
USAGE
- Challenging transit times
- Challenging ambient conditions
- On/off service
- Safety-instrumented system
ATTACHMENT TO
- Linear actuator, single acting
- Linear actuator, double acting
- Rotary actuator, single acting
- Rotary actuator, double acting
EXPLOSION PROTECTION
- Type of protection "Flameproof enclosure"
- Without certification
COMMUNICATION
- HART®
CONTROL LOOP
- 4 to 20 mA
OPTIONAL SOLENOID VALVE
- With
VALVE DIAGNOSTICS
- With
Special features
- Electropneumatic Ex d positioner with HART® communication
- Certified according to IEC 61508/SIL
- Preset parameters for on/off valves in safety-instrumented systems
- Integrated EXPERTplus diagnostics with partial stroke testing (PST) function
- Optional fault alarm output for alarms generated by the EXPERTplus valve diagnostics
- Die-cast aluminum housing
- Attachment to linear actuators according to IEC 60534-6 or SAMSON integral attachment
- Attachment to rotary actuators according to VDI/VDE 3845
- Attachment to double-acting actuators with Type 3710 Reversing Amplifier
- Any desired mounting position of the positioner (but not suspended)
- Simple one-knob, menu-driven operation also in hazardous areas
- Easy-to-read display in any mounting position thanks to rotatable reading direction
- Configurable with a computer over the SSP interface using the TROVIS-VIEW software
- Variable automatic start-up thanks to four different initialization modes
- Calibrated travel sensor without gears susceptible to wear
- Sub (substitution) initialization mode allows the positioner to be started up in case of emergency whilst the plant is running without having to change the valve position.
- All parameters saved in non-volatile EEPROM
- Two-wire system with small electrical load between 300 and 350 Ω at 20 mA
- Adjustable output pressure limitation
- Adjustable tight-closing function
- Automatic zero monitoring
- Integrated temperature sensor and operating hours counter
- Self-diagnostics
- Messages as condensed state conforming to NAMUR Recommendation NE 107, issued over a fault alarm contact or optional analog position transmitter
Accessories
- Pressure gauge
- TROVIS-VIEW Software (free of charge)
- Device integration files for engineering tools and systems
Options
- - - -
Information
- WA 336 Flyer: TROVIS SAFE 3730-6 and TROVIS SAFE 3731-3 PositionersSafe with Automated On/off Valves[EN][DE]
- WA 335 Special Print: Digitalization of Industrial Control Valves
 [EN][DE]
- WA 333 Special Print: Safety in the Process Industry
 [EN][DE]
- WA 300 Flyer: WirelessHART
 Positioners in a WirelessHART® network
 [EN][DE]
- WA 310 Brochure: MASTERMINDS BEHIND EVERY VALVE MOTIONTaking a Closer Look at SAMSON Positioners[EN][DE]
- WA 353 Sonderdruck: Wunschdenken oder Wirklichkeit?
 [DE]
- T 8387-3S TROVIS SAFE 3731-3 Electropneumatic Ex d Positioner
 with HART® communication
 [EN][DE]
- T 8389S TROVIS SAFE 3731-3 Electropneumatic Positioner
 EXPERTplus Valve Diagnostics
 [EN][DE]
- T 8350 Information Sheet of Valve Accessories
 Positioners · Limit Switches · Solenoid Valves · Valve AccessoriesSelection and Application[EN][DE]
- T 6661 TROVIS-VIEW software
 TROVIS 6661
 [EN][DE][JA]
Support
DXF file from data sheet
- T 8387-3S [ZIP]
Certificates
Only up-to-date documents are shown in the product selector. Check the documentation site for a list of all documents available.
					Pin product
				
Pin items on your list and contact us if you have any product-related questions.